316 Appendix A Installation
Installing a printer
The console supports parallel printers, including most laser printers.
Printer functions are described in Chapter 21 Printing, page 249. Follow
these steps to install the printer:
1. Insert the parallel printer cable into the connector labeled Parallel
Printer on the back panel of the console.
2. Insert the opposite end of printer cable into printer.
3. Turn printer power switch on, and verify that printer is on line.
Console connector Printer connector
DB25F Centronics D36
Pinout Signal Pinout
1 STRB 1
2D0 2
3D1 3
4D2 4
5D3 5
6D4 6
7D5 7
8D6 8
9D7 9
10 ACK 10
11 Busy 11
12, 13 Not used 12, 18
14 to 17 not connected 13 to 15, 17, 19 to 36
18 to 25 Ground 16
Installing Remote Focus Unit
The Remote Focus Unit (RFU) allows you to set channel levels, check
dimmers or run cues from remote locations.
To install the RFU, follow these steps:
1. Verify that RFU power switch is turned Off. (Unit is off when switch
is in the position toward the bottom edge of the RFU.)
2. Insert the RFU cable into the connector on the back of the console or
Remote Interface labeled, RFU.
3. Turn RFU power switch to On.
RFU console connector
XLR 6-pin female
RFU pinout
1 Data (+) (to RFU)
2Data ()
3 Data (+) (from RFU)
4Data ()
5 Common (AC ground)
6 +12 Vdc (fused, 2 amp)
Seitenansicht 329