Seitenansicht 163
150 Ion Operations Manual
Using Record Only
Modifying existing cues using [Record Only] is considered a “selective store” function. As such, it
adds or modifies only manual data to the target cue, but leaves any other data that was already in
the cue intact and does not include playback values from other cue lists or submasters. [Record
Only] is a good way to modify existing cues without including contributions from other playbacks in
the cue. In that way, it is very similar to update.
[Record Only] [Enter] [Enter]- adds the current manual data to the selected cue.
[Record Only] [Cue] [x] [Enter] [Enter] - adds the current manual data to cue “x”.
Move To
You can use the command {Move To} to move a cue from one location in the cue list to another.
[Cue] [4] <More SK> {Move To} <Cue> [8] [Enter] - moves the contents of cue 4 to cue 8.
Cue 4 is removed entirely. If cue 8 already existed, a confirmation will be required before
replacing cue 8 (unless confirmations have been disabled in setup). Any contents of cue 8 will
be replaced entirely.