7) Connector strips shall support optional LED indicators to indicate the presence of
power at each local circuit. The indicator shall be red in color and mounted in the
connector strip
a) The LED indicator shall be mounted in the lower right corner of the outlet panel
b) The LED indicator shall be mounted in the connector strip trough directly below
the outlet panel.
c) The LED indicator shall be mounted in the center of the 3” plate directly below
the circuit label for pigtail circuits
C) Junction Boxes
1) Gridiron junction boxes shall be available to accommodate SO or SOW cable wiring
into connector strips mounted to non-fixed locations
2) Junction Boxes shall be fabricated from 16-gauge cold rolled steel with 14 gauge
end panels. They shall be finished with fine-textured, scratch-resistant, black powder
coat paint. Cover(s) shall be 16-gauge cold rolled steel and hinged to allow mounting
in any direction.
4.2) ALTERNATE LIGHTING CONSOLE AND ACCESSORIES
A. General
1. The lighting control console shall be a microprocessor-based system specifically designed to
provide complete control of stage, studio, and entertainment lighting systems. The console shall be
the Ion as manufactured by Electronic Theatre Controls, Inc.,.
2. The system shall provide control of 3072 outputs on a maximum of 10,000 control channels,
patched across any number up to 99,999. Output shall be distributed over an Ethernet network
using Net3/ACN, ETCNet 2, Avab and/or ArtNet protocols. The user shall be able to control the
application of protocols at an individual address level.
3. The system shall support full bi-directional RDM communication with compatible devices via
Net3 DMX/RDM Gateways. RDM communication shall adhere to ANSII standard E1.20-2006
Entertainment Technology – RDM – Remote Device Management over DMX512 Networks.
Supported RDM features shall include:
a. Discovery and identification of RDM capable devices.
b. Setting of start addresses, operating modes and additional settings as exposed by
connected devices and controllable via RDM.
c. Viewing of Sensor data as provided by connected devices.
d. Error reported as provided by connected devices.
4. A maximum of 10,000 cues, 999 cue lists, 1000 groups, 1000 presets, 4 x 1000 palettes
(Intensity, Focus, Color and Beam), 1000 effects, 1000 macros and 100 curves may be contained
in non-volatile electronic memory and stored to an onboard hard disk or to any USB storage
device.
5. Recorded cue lists may be played back simultaneously on a maximum of 200 faders.
Channels shall respond to cue information by last instruction with discrete rate control provided for
all cues. The console may be placed in Tracking or Cue Only mode by the user as a system default
and overridden on individual record actions as required. HTP/LTP intensity flags, assert,