Maintenance and Troubleshooting 257
Using Remote Macros
The facepanel provides remote macro inputs through the connector on the back panel
labeled Remote Macro (Remote Go on older Expression-style facepanels). A user-supplied
remote device connects to the facepanel via a 24 AWG, aluminum-shielded, multi-
conductor cable with one twisted pair designated for each switch (Belden 9507 S-R PCV
Insulated or Alpha 5477 80 Deg. C 300 V PVC). The cable connector at the remote device
will vary depending on the device itself.
Pin
Expression/Insight
(DB-25 female)
ETCNet2 Video Node
(DB-25 female)
Express (DB-15 female)
Connector Face
1 – Macro 1,901 – Macro 1,901 + Macro 1,901
2 – Macro 1,902 – Macro 1,902 – Macro 1,901
3 – Macro 1,903 – Macro 1,903 + Macro 1,902
4 – Macro 1,904 – Macro 1,904 – Macro 1,902
5 – Macro 1,905 – Macro 1,905 + Macro 1,903
6 – Macro 1,906 – Macro 1,906 – Macro 1,903
7 – Macro 1,907 – Macro 1,907 + Macro 1,904
8 – Macro 1,908 – Macro 1,908 – Macro 1,904
9 Not Connected Not Connected
Remote Trigger - normally closed
(30V 1 amp max)
10 Ground Ground
Remote Trigger - normally open
(30V 1 amp max)
11 + 12 Vdc + 12 Vdc
Remote Trigger - common
(30V 1 amp max)
12 Not Connected
Remote Trigger - normally closed
(30V 1 amp max)
Ground
13 Not Connected
Remote Trigger - common
(30V 1 amp max)
Ground
14 + Macro 1,901 + Macro 1,901 + 12 Vdc fused
15 + Macro 1,902 + Macro 1,902 + 12 Vdc fused
16 + Macro 1,903 + Macro 1,903
17 + Macro 1,904 + Macro 1,904
18 + Macro 1,905 + Macro 1,905
19 + Macro 1,906 + Macro 1,906
20 + Macro 1,907 + Macro 1,907
21 + Macro 1,908 + Macro 1,908
22 Not Connected Not Connected
23 Ground Ground
24 + 12 Vdc + 12 Vdc
25 Not Connected
Remote Trigger - normally open
(30V 1 amp max)